In this article, we are going to share the working principle of aqualarm as a switch for heavy duty pumps
When a predetermined amount of fluid pressure is reached, a pressure switch will open an electrical contact
aqualarm heavy duty pump switch
This happens automatically
The switch will make an electrical connection whenever there is a predetermined amount of change in the pressure, either up or down
Pressure switches are utilized in a wide variety of contexts, including HVAC (mechanical ventilation and air conditioning) systems, well pumps, home heating equipment, and many more
Please read our page on the subject if you require a diagram that is associated with a pressure switch
It is imperative that a pressure switch and a pressure transducer be differentiated from one another
A device known as a pressure transducer is one that initially generates an electric signal in order to monitor pressure
Check out our comprehensive technical page on pressure transducers to learn more about these instruments
A spring and either a diaphragm or a piston are utilized in a mechanical pressure switch so that the level of pressure required to activate the micro-switch can be adjusted
The assertion of the spring can be adjusted using either a set screw or a knob
The spring acts as a counterbalance to the pressure that is present at the inlet
The amount of force that is applied to the switch directly correlates to the amount of pretension that is created in the spring
This relationship is exactly one-to-one
When the pressure drops, the switch goes back to the position it was in when it was first turned on
The amount of time something needs to get back to its initial condition after being turned off is referred to as its hysteresis
Typically, this is expressed as a percentage of the value at the switching point, such as 20% of that value
The hysteresis of mechanical switches is often defined by the manufacturer and cannot be altered by the user
This is the case in the majority of cases
On pressure switches, there are commonly three different types of contacts: normally open (NO), normally closed (NC), and changeover (SPDT)
aqualarm heavy duty pump pressure switch
The changeover connections can operate in either a NO or an NC mode, depending on the situation
The mechanical variant of a pressure switch is superior in terms of its capacity to withstand high voltages and currents when compared to its electronic counterpart
They are so suitable that they can be used for either increasing or decreasing pressure, depending on the contact they have with the object
We go into great detail on the topic of how to adjust the sensitivity of mechanical pressure switches
An electronic pressure switch will use an electrical pressure sensor in order to be able to detect any changes in the pressure of the inlet
The switching functionality of these devices can be set using the digital displays
The switch point could have been predetermined by the manufacturer, or it could have been altered on-site to better suit individual requirements
The user has the ability to personalize various features of the device, such as the switch point, output signals, hysteresis, delay time, and more
Electronic pressure switches feature a number of desirable characteristics, including the ability to be programmed, digital displays, adaptability, accuracy, ingress protection, and stability, which makes them an excellent choice for automated and controlled equipment systems
A pressure switch is a sort of single pole double throw (SPDT) switch that is operated mechanically
The housing for the switch only has a single pressure intake despite the fact that it houses all of the relevant pieces
The input pressure will push a piston against a spring that has a known resistance force
This will cause the piston to move
Piston movement activates the micro switch, moving it between the normally closed (NC) and normally open (NO) positions through an operating pin and an insulated trip button, respectively
Adjusting the pressure threshold at which the micro switch switches between the NC and NO positions is accomplished by turning the trip-setting nut, which controls the spring pocket depth
Because of this change in depth, it is possible for the spring resistive force to increase or decrease, which corresponds to a certain pressure that is required to activate the micro switch
The inlet pressure, denoted by H, exerts a downward force on the moving piston, working in opposition to the force that is generated by the range spring
When the force of the inlet pistons is greater than the force of the opposing spring, the operational pin is forced into the insulated trip button
aqualarm heavy duty pump types of pressure switch
This causes the trip button to be activated
Simply pressing this button will cause the micro switch to go from the NO position to the NC position
When there is not enough pressure to overcome the tension of the spring, the piston, pin, and button will all release from the micro switch
After that, the NO position is moved to the NC position, which finishes off the circuit
Before you send in your application, you should consider the following criteria:
1- Type of media: The medium that is utilized must be appropriate for the housing and the material that is used for sealing
Butadiene rubber can be used with a variety of fluids, including air, hydraulic or machine oil (NBR)
For application in aquatic situations, ethylene propylene diene monomer (EPDM) is an excellent alternative
The following types of materials are utilized with pressure switches the majority of the time:
Hydrostatic fluid
Heating with oil
Turpentine
Petrol/gasoline
Air
Water
2-Pressure: The maximum resistance possible under working pressure is required
In conditions of low pressure or vacuum, it is best to employ a design that utilizes a diaphragm
When dealing with high pressure, the best designs to use are those based on pistons
3-Temperature: Both the highest and lowest temperatures that can be reached must be recorded, and the apparatus must operate correctly within specified temperature ranges
4-Repeatability: Repeatability, also known as accuracy, is the degree to which an instrument can be relied upon to consistently and repeatedly return to the same set point
There are several applications for pressure switches, and the type you select will be determined by the degree to which the device you are working on requires accuracy
In most cases, the precision of designs using diaphragms is superior to that of designs utilizing pistons
5-Hysteresis: The discrepancy between the switch point and the reset point is known as the hysteresis of the system
In the event that the reset point is set too high, the switch will continue to be active for a considerable amount of time
Because of this, if the reset point of the switch is set too low, it will repeatedly toggle between the on and off positions
The hysteresis of a mechanical pressure switch cannot be changed once it has been manufactured, whereas the hysteresis of an electric pressure switch can be altered
6-Type of Pressure Switch: The type of pressure switch known as a diaphragm design should be selected for use in situations involving low pressure and vacuum
Utilize one that is designed with a piston for usage in high-pressure settings
7- Approvals: Our pressure switches have been given ATEX certification for zones 1, 2, and 22, making them suitable for use in environments where there is a risk of an explosion occurring
8-Electric or Mechanical Pressure Switch: Mechanical pressure switches are more affordable than their electronic counterparts, but offer fewer opportunities for customization
Electronic pressure switches are more versatile (such as pressure set point and hysteresis)
aqualarm heavy duty pump industrial pressure switch
In the following list, we mentioned a few of the many applications that a pressure switch can have in both everyday life and industrial settings:
In heating, ventilation, and air conditioning (HVAC), gas cylinders, air pumps, and other similar systems, air compressor pressure switches are utilized to monitor and control the air pressure
For any further information, take a look at our piece that discusses adjusting the pressure switches on air compressors
If the oil pressure in a motor falls below a given threshold, the switch that doubles as an actuator and a sensor will become active and cause the motor to stop
Pressure switches are an important and helpful safety component for both commercial and residential heating systems
They are found in furnaces
When the heating system is turned on, the air pressure is checked, and the system is turned off if it has too little pressure
A well pump pressure switch can be utilized in either a residential or commercial setting to control the amount of pressure that is present in the water supply system
This helps to ensure that the well is not over-pressurized
On residential, commercial, and agricultural water pumps, pressure switches are installed for the purpose of automating the regulation of the water supply
Vacuum pressure switches are used to identify the presence of negative pressure
These components are utilized in a wide variety of home appliances, including air compressors, boilers for residential usage, electric heaters, and transmission systems